|
Nordicana D108 / DOI : 10.5885/45810XD-C9F549F3E93040BD
|
Température de l'air et du sol, humidité de l'air et données de caractérisation des sites dans une région de taïga du bouclier canadien, Yellowknife, Territoires du Nord-Ouest, Canada Air and ground temperature, air humidity and site characterization data from the Canadian Shield taiga near Yellowknife, Northwest Territories, Canada
|
Nicholas Brown 1,
Emilie Stewart-Jones 1,
Julia Riddick 1,
Olivia Meier-Legault 1,
Steve Kokelj 2
Kumari Karunaratne 2,
Stephan Gruber 1,
1 Carleton University
2 Northwest Territories Geological Survey
|
Résumé / Abstract
Un réseau des capteurs de température et d’humidité a été installé près de Yellowknife, Canada afin d’établir 28 sites qui représentent la variabilité du paysage. Le bût du travail était de mesurer la variabilité spatiale de la température du sol et des conditions climatiques près de la surface. Les sites choisis sont différenciés par leur végétation, aspects solaires, géologie superficielle, et élévation. Ces données seraient utiles pour étudier les effets des caractéristiques du paysage sur les températures du sol et pour évaluer la performance des modèles. Les parcelles d'étude, mesurant 15m x 15m, ont été choisies pour représenter les différentes facettes du paysage. Pour chaque parcelle, jusqu’à quatre sous-parcelles ont été choisies pour représenter la variabilité interne des caractéristiques de surface. Pour chaque parcelle il y a une description de la topographie, des dérangements, des caractéristiques de surface, de la végétation, ainsi qu’une mesure de l’indice de surface foliaire. Pour chaque sous-parcelle, nous avons installé un capteur de température à 10 cm de profondeur. À certains sites, des capteurs de température et d’humidité de l’air ont été installés à 2 m au-dessus du niveau du sol. De plus, sept capteurs de temperature ont été installés dans des parois rocheuses horizontales et verticales. Tous les capteurs ont été réglés sur l'heure UTC et programmés pour enregistrer des données à toutes les 20 minutes. L'emplacement des parcelles d'étude a été choisi pour fournir un accès facile à partir de Yellowknife tout en étant suffisamment éloigné de la ville pour être rarement dérangé par les gens. Dans l'ensemble, les sites ont été choisis pour représenter les conditions de base plutôt que les perturbations. Cependant, certaines zones montrent des signes de perturbation humaine tels que des lignes de coupe qui auront presque certainement affecté le régime thermique actuel. De plus, certains sites se trouvent clairement dans un pergélisol en cours de dégradation.
A network of temperature and humidity sensors was deployed near Yellowknife, Canada to establish 28 distinct study sites reflecting landscape variability. The field campaign was designed to measure the spatial variation of near-surface climatic conditions and ground temperature. The sites differ in their vegetation type and abundance, surficial geology, solar aspect, slope, and elevation. The data will be beneficial for understanding the effects of landscape characteristics on ground temperature and for providing data to conduct systematic model evaluation.
Individual study plots measuring 15 m × 15 m were selected to represent different facets of the landscape. For each plot, up to four sub-plots were selected to represent the diversity of surface characteristics within the plot area. Each plot was characterized according to surface features, disturbances and topography. Sub-plot metadata included vegetation type and abundance as well as leaf-area index. At each sub-plot, a single-channel temperature logger was installed approximately 10 cm below the ground surface.
At other sites, air temperature and humidity sensors were installed 2 m above the ground surface. In addition, seven temperature sensors were installed into horizontal and vertical rock surfaces across the study area. Instruments were programmed to record data every 20 minutes. All instruments were set to UTC time. Time series have been aggregated to hourly and daily averages.
Study plot locations were chosen to provide easy access from Yellowknife while at the same time being sufficiently far from town so as to be infrequently disturbed by people. Overall, sites were selected to represent baseline conditions rather than disturbance . However, some areas show signs of human disturbance such as cutlines which almost certainly will have affected the present thermal regime. In addition, some sites are clearly within degrading permafrost.
|
Citation des données / Data citation
|
Brown, N., Stewart-Jones, E., Riddick, J., Meier-Legault, O., Kokelj, S., Karunaratne, K., Gruber, S., 2022. Température de l'air et du sol, humidité de l'air et données de caractérisation des sites dans une région de taïga du bouclier canadien, Yellowknife, Territoires du Nord-Ouest, Canada, v. 1.0 (2016-2021). Nordicana D108, doi: 10.5885/45810XD-C9F549F3E93040BD.
|
Brown, N., Stewart-Jones, E., Riddick, J., Meier-Legault, O., Kokelj, S., Karunaratne, K., Gruber, S., 2022. Air and ground temperature, air humidity and site characterization data from the Canadian Shield taiga near Yellowknife, Northwest Territories, Canada, v. 1.0 (2016-2021). Nordicana D108, doi: 10.5885/45810XD-C9F549F3E93040BD.
|
Carte de localisation / Location map
|
|
Publié / Published
|
Historique des versions / Version history
|
Vous pouvez faire une demande pour obtenir les données des versions antérieures à nordicana@cen.ulaval.ca. You can request for data from previous versions at nordicana@cen.ulaval.ca.
|
Version 1.0 (2016-2021) - Mise à jour le 30 novembre 2022 / Updated November 30, 2022
|
Sites de mesure / Measurement sites
|
|
Documentation supplémentaire / Supplementary material
|
|
|
|
|
|
|
|
Téléchargement (Cliquez le +/- pour les détails) Download (Click +/- for details)
|
Les fichiers téléchargés en format ZIP contiennent un fichier d'instruction et un fichier de données en format texte (ASCII). SVP! Citez toujours les données lorsque vous les utilisez.
|
Download ZIP file contains a readme file and a data file in text format (ASCII). Please! Always quote citation when using data.
|